Bubble C Pap

/Bubble C Pap
Bubble C Pap2019-02-07T05:18:38+00:00

Model:CPAP-2000 With Humidifier HU-310, along with flow meter Mixer

Model: CPAP-2100 With Humidifier HU-310, along with Blender

Model: CPAP-3000 With Humidifier AHU-350, along with flow meter Mixer

Model: CPAP-3100 With Humidifier AHU-350, along with Blender

(BUBBLE CPAP SYSTEM)

Bubble C-PAP is an unique system that can deliver high flows of Air or Oxygen ranging from 1 to 15 LPM
Clinical studies have proven the usefulness of high flow of gases when warmed at body temperature and humidified
upto99 to100% relative humidity and delivered through nasal cannula. Heat and Humidity prevents airway water loss,
,airway cooling, thickened secretions, nasal irritation & bleeding.
The Bubble C-PAP allows delivery of breathing gases heated to body temperature & at nearly 100% relative humidity
by nasal cannula without drying or cooling the airways, which was not possible in the conventional bubble humidifiers.
Most respiratory diseases of the neonate occur as a result of the immaturity of the premature neonate’s lungs. The
respiratory system is under developed and adequate gas exchange does not take place naturally, with this, there is a need
for providing external respiratory support.
Some of the benefits of using Bubble CPAP are:

Bubble C-PAP Effectively maintains Functional Residual Capacity (FRC)

Most lung diseases that lead for respiratory failure are commonly associated with a reduced FRC .Maintaining FRC is
very important to premature neonates who have a greater tendency of airway closure when FRC falls below closing
volume.

Bubble C-PAP Helps reduce the infant’s Work of Breathing(WOB)

There is a decrease In infant’s minute volume and respiratory rate .Chest vibrations are caused by the pressure oscillations from the bubbling. These pressure oscillations are reverted back into the infant’s airway and may provide an alternate form ofgas exchange through the principle of facilitated diffusion.

  • Comes with compact gas mixer for air and oxygen (Tubeless Construction).
  • Range step less 21%to100% of oxygen. Inlet foe gas pressure is 50 psi.
  • Integrated flow meter unit with range from 0∼15I/ min.
  • Alarm system for gas supply drop.
  • Unique Design and easy to use.
  • Integrated pole assemble for mounting all the items.
  • Respiratory humidifier with humidification chamber.

Specification

lnput flow range 4∼15 lpm

Fi02 range 21 ∼ 100%

Set CPAP Pressure Range Maximum 3 ∼ 10cmH20

Pressure Limit 1 7cm H20 at 8 lpm

Operating Temperature Range 18∼ 260 Storage

Temperature Range -10 ∼500 C

Power Requirements 220VAC, 50/60Hz

Optional

  • Air compressor , oxygen Analyser..
  • Flow meter unit with needle valves for Air & Oxygen and can be used as an option for blender.
  • Delivery system(includes Humidification Chamber, Pressure relief manifold, single heater patient circuit, Gas supply
  • Patient interface includes nasal prongs, nasal tubings & Infant bonnets.
  • line)

Newborn/Premature baby special equipment:

a sort of equipment used by medical staff who make rescue measure by using different
concentration of oxygen, suitable for neonate especially premature infant to treat the oxygen damage
and other complications, such as retinopathy of premature children (ROP) and chronic lung disease(CLD)
due to absorbing high flow and concentrations oxygen for a long time. The product complies with
requirement of the “Guide”. It must use the device that mixed with air and oxygen ,strictly gasp the
indications and ways of using oxygen, monitor and adjust the concentration in time according to the
condition of patients to avoid excessive fluctuation.

Product performance Characteristics:

  • It is used on the course that strictly requires for oxygen concentration, such as hood, nasal
    catheter, incubator, infant resuscitator, heart lung machine.
  • The different of medical oxygen will be configured by adjusting the proportion of oxygen and air.
  • The surface is processing with anodic oxidation.
  • Equipped with a regulating valve that can adjust the proportion of oxygen concentration, and a
    device that make the pressure stable, in order to output the constant pressure.
  • Adjust the oxygen concentrations and flow respectively.
  • The structure with double output: port it can supply gas for one or more patients at the same
    time.
  • Inside an alarm system of different pressure, when alarming, the safety valve starts
    automatically and produces the mixture gas continuously to ensure the safety of patients:

Enquiry

Model:CPAP-2000 With Humidifier HU-310, along with flow meter Mixer

Model: CPAP-2100 With Humidifier HU-310, along with Blender

Model: CPAP-3000 With Humidifier AHU-350, along with flow meter Mixer

Model: CPAP-3100 With Humidifier AHU-350, along with Blender

Performance Parameter
Model (AOB-001)

  • Oxygen Concentration adjustment: 21% to 100%
  • Flow Regulations:0~18 LPM (optional dual flow meter dual output)

Model (AOB-002)

  • Optional dual output matching
  • Oxygen Concentration adjustment: 21 % to 100%
  • Optional flow meter/inhaler

Model (AOB-003)

  • Oxygen Concentration adjustment: 21 % to 100%
  • Flow: 0.1LPM~1.0LPM(Dual output)
    0.1LPM~1.0LPM

Model (AOB-004)

  • Oxygen Concentration adjustment: 21 % to 100%
  • It can adjust 0.1 to 10 LMP pressure in single output with different knobs as required.

Enquiry

RESPIRATORY HUMIDIFIER

  • It can match with imported and domestic ventilator, CPAP for heating and humidifying
  • It is constant and reliable because of its microprocessor and contact less control
  • Ergonomic design can utilize the space effectively
  • It is convenient to monitor by digital display
  • It controls the temperature automatically and equipped with over heat protection device
  • The maximum temperature of heating plate is not more than 85 0 C
  • It controls the temperature automatically in the range 28 0 to 40 0 C
  • The accessories of device clean with conventional disinfectant, high pressure sterilization.

Enquiry