FEATURES
- Micro Processor based servo-controlled electronic controller
- Source box made with high quality F.R . grade fiber material for
extra safety from electric shocks and corrosion - Newly designed oval shape baby tray with four sides collapsible
clear acrylic panels,head up & down tilting facility for baby tray - Baby Matress density aprox. 21-25 Kg./m3 with removable
washable cover. - LED Examination Lamp
- German make ceramic heater with parabollc reflector
- Maintains uniform temp across the mattress with swlvellng source box easy to take x-ray procedures
- Skin/Air/ Pre warm/ Manual control with LCD Screen
- Thermistor Based Skin/Air Sensor
- Visible LED Display for Skin/Air Temperature/Set Temperature & % of heater power output
- LED Indicator for selected mode
- Bright back-light LCD Screen for alarm messages,Selected mode,timer Dlsplay & SkinTemp. in C° & F°
- IntegratedTimer 1-59Min With count-up & count -Down Feature & APGAR
- Temp.range -Skin-34 to 38°C (User Pre-settable),Air -Room Temp.to 39°C
- Accuracy:+/- 0.1C°,Resolution: 0.1°C
- If the Heater Power is 100% for more than 15 mins. heating comes down to 25%( Check Sensor Position)
- Heater is unplug or faulty-Heater open.
- Heater Power Drive fall -Check Power Drive
- Manual Mode-User is allowed to set the heater power from
25%-100% with Increment of 5%. Tlme Limit 15 min. - Pre-warm Mode• User Is not allowed to set heater power more
than 25%. Adjustable Heater Power 0-25% with increment of 5% Time limit 30 minutes - Heater Out put -0-100% inincrements of 5%
- Control Unit- Auto Over- temp.Cutoff With audio-visual alarms
according to Preset Temp to avoid Over Heating - L.C.D. Display Reports: systems errors,sensor failure alarm and visual
message on LCD For High/Low,Over /Under Temp.for skin & air,Heater Failure, - Power Control device Failure. Vlsual /Audio Alarm for Power failure
- Latest high bright super flux LED Top surface phototherapy with
digital timer, integrated with heater source( Only In OCS 5100) - Facility to Incorporate Under Surface Phototherapy.
- Keypad lock Facility
- OperatfngVolatage:220V-2.40V 50HzAC
- 2/3 Drawer (Optional)
- Peripheral temperature Display (Optional)
Resuscitation Attachment for OCS 5100/5000( Open Care system) - Infant Resuscitator will safely inflate the Baby’s lungs and provide optimum oxygenation by delivering consistent PlP & PEEP/CPAP with each breathe avoiding the risks associated with under or over inflation of uncontrolled pressures.
- The patient T-Piece can connect to Neonatal masks or Endotraceal tubes directly.
- Different sizes of face mask which provides flexible in usage for different babies
- lnspiratory high pressure safety cut-off relief setting
- Peak inspiratory Pressure setting(PIP)
- Positive and expiratory pressure setting(PEEP)
- Works at flow range from 5L/min. to 15L/min.
- Medical grade monometer to monitor PIP & PEEP delivered.
- Inlets for oxygen and air with suitable dehumidifier at air inlet.
- Integrated slow suction unit with vacuum regulator,vacuum gauge and auto
cleavable suction jar and tubings. - Power requirement :220V-2.40V 50HzAC